SCID Instrument Descriptions and Histories


Model Measurement
Notes (below)
Units Install
Date
Removal
Date
Current
SN
Current
CF
SD-201 Wind Direction o from N 01/01/2000 - T2042
T2041
T2040
0.288 o/mV
The average wind direction at 10 feet and the mean wind direction vector at 80 and 140ft. The standard deviation of the wind directions at 80 and 140ft are also recorded.
SS-201 Wind Speed m/s 01/01/2000 - R3315
W4365
0.0440 m/s/pulse+0.3035 m/s
0.0441 m/s/pulse+0.3230 m/s
The mean wind speed at 80 and 140ft. The max wind speed are also recorded.
CSI Temperature oC 01/01/2000 - 107-U 1.0 oC/mV
The Temperature Sensor is mounted at 3 meters.
AB-2A Pressure mBar 01/01/2000 - 4G0233 0.104 mBar/mV+800mBar
The Pressure Transmitter is mounted at 2 meters.
- CR10X Battery Voltage V 01/01/2000 - - -
CR10X external battery voltage.
Notes:
  • Data Sample rate is 1/sec, with 10-min averages and 24-hr data.
  • 24-hr data can only be retrieved using the "Full Raw Data" selection.
  • Raw data files were downloaded directly from Campbell Scientific CR10X datalogger using PC208W.

[NREL] [MIDC] [SCID]