R#SiteDateTimeCreation TimeInstrumentConditionTypeAlignment MagnitudeAlignment DirectionVentilatorDessicantShadingUsernameSkyTechnicianCommentMIDC ID
1BMS07/31/200809:31:2207/31/2008 09:31:22Direct CH1 Clean/OKDIRdmyersDaryl MyersClean ;
2BMS07/31/200809:31:2207/31/2008 09:31:22Direct CUVA2Clean/OKDIRdmyersDaryl MyersClean ;
3BMS07/31/200809:31:2207/31/2008 09:31:22Direct CUVB2Clean/OKDIRdmyersDaryl MyersClean ;
4BMS07/31/200809:31:2207/31/2008 09:31:22Direct LI-201 Clean/OKDIRdmyersDaryl MyersClean ;
5BMS07/31/200809:31:2207/31/2008 09:31:22Direct NIP #1Clean/OKDIRdmyersDaryl MyersClean ;
6BMS07/31/200809:31:2207/31/2008 09:31:22Direct NIP #2Clean/OKDIRdmyersDaryl MyersClean ;
7BMS07/31/200809:31:2207/31/2008 09:31:22Direct RG780 NIPClean/OKDIRdmyersDaryl MyersClean ;
8BMS07/31/200809:31:2207/31/2008 09:31:22Photometer TWCClean/OKDIRdmyersDaryl MyersClean ;
9BMS07/31/200809:31:2207/31/2008 09:31:22Global 501AClean/OKGLOdmyersDaryl MyersClean ;
10BMS07/31/200809:31:2307/31/2008 09:31:23Global CM22Clean/OKGLOOKdmyersDaryl MyersClean ; Ventilator OK
11BMS07/31/200809:31:2207/31/2008 09:31:22Global CM3Clean/OKGLOdmyersDaryl MyersClean ; CNR1 Level OK
12BMS07/31/200809:31:2207/31/2008 09:31:22Global CM6bClean/OKGLOdmyersDaryl MyersClean ;
13BMS07/31/200809:31:2207/31/2008 09:31:22Global CUVA1ProblemGLOdmyersDaryl MyersProblem white smudges on INSIDE dome?? At about 270-300 Az and 50 el;
14BMS07/31/200809:31:2207/31/2008 09:31:22Global CUVB1ProblemGLOdmyersDaryl MyersProblem white smudges on INSIDE dome?? At about 270-300 Az and 50 el;
15BMS07/31/200809:31:2207/31/2008 09:31:22Global LI-200 #1Clean/OKGLOdmyersDaryl MyersClean ;
16BMS07/31/200809:31:2207/31/2008 09:31:22Global MS210WClean/OKGLOdmyersDaryl MyersClean ;
17BMS07/31/200809:31:2307/31/2008 09:31:23Global Photometric LI-210Clean/OKGLOdmyersDaryl MyersClean ;
18BMS07/31/200809:31:2207/31/2008 09:31:22Global PSPClean/OKGLOdmyersDaryl MyersClean ;
19BMS07/31/200809:31:2207/31/2008 09:31:22Global PSP VentClean/OKGLOOKdmyersDaryl MyersClean ; Ventilator OK
20BMS07/31/200809:31:2307/31/2008 09:31:23Global PYR-PClean/OKGLOdmyersDaryl MyersClean ;
21BMS07/31/200809:31:2207/31/2008 09:31:22Global Quantum LI-190Clean/OKGLOdmyersDaryl MyersClean ;
22BMS07/31/200809:31:2207/31/2008 09:31:22Global RG780 PSPClean/OKGLOOKdmyersDaryl MyersClean ; Ventilator OK
23BMS07/31/200809:31:2207/31/2008 09:31:22Global SP LiteClean/OKGLOdmyersDaryl MyersClean ;
24BMS07/31/200809:31:2207/31/2008 09:31:22Global TSP-1Clean/OKGLOdmyersDaryl MyersClean ;
25BMS07/31/200809:31:2207/31/2008 09:31:22Global TSP-700Clean/OKGLOOKdmyersDaryl MyersClean ; Ventilator OK