MIDC/AIM Location Database
Total Records: 20, displaying 1-20

R#Serial NumberMeasurementInstall DateLocationNotesDate RemovedStateOwnerInstrument_Virtual::MakeInstrument_Virtual::ModelMIDC ID
1083EDry Bulb Temperature and Relative Humidity11/01/2012NELHAOutside air temperature and relative humidity (model 083E) inside in a naturally aspirated radiation shield mounted at 2 meters.
The temperature is measured by a thermistor using the half bridge.
The dewpoint temperature is calculated by the data logger using temperature and humidity.
04/16/2021HINELHATRH
2N11762Dry Bulb Temperature and Relative Humidity04/16/2021NELHAOutside air temperature and relative humidity (model 083E) inside in a naturally aspirated radiation shield mounted at 2 meters.
The temperature is measured by a thermistor using the half bridge.
The dewpoint temperature is calculated by the data logger using temperature and humidity.
HINELHAMetOne083E-1-13TRH
3126933Global Horizontal11/01/2012NELHATotal Hemispheric shortwave irradiance as measured by an Kipp & Zonen Thermopile Pyranometer.
Note: For data prior to 12/17/2012, negative values from the thermopile sensor were set to zero by the data logger.
04/07/2015HINELHAKipp & ZonenCMP11GH
4140710Global Horizontal04/07/2015NELHATotal Hemispheric shortwave irradiance as measured by an Kipp & Zonen Thermopile Pyranometer. 02/09/2017HINELHAKipp & ZonenCMP10GH
5126933Global Horizontal02/09/2017NELHATotal Hemispheric shortwave irradiance as measured by an Kipp & Zonen Thermopile Pyranometer. 02/05/2019HINELHAKipp & ZonenCMP11GH
6140710Global Horizontal02/05/2019NELHATotal Hemispheric shortwave irradiance as measured by an Kipp & Zonen Thermopile Pyranometer. 04/16/2021HINELHAKipp & ZonenCMP10GH
7126933Global Horizontal04/16/2021NELHATotal Hemispheric shortwave irradiance as measured by an Kipp & Zonen Thermopile Pyranometer. HINELHAKipp & ZonenCMP11GH
8Q99293Global PAR04/23/2013NELHAThe LI-COR LI-190 quantum sensor measures photosynthetically active radiation (PAR) in the 400 to 700 nm waveband.04/07/2015HINELHALI-CORLI-190PAR
9Q52979Global PAR04/07/2015NELHAThe LI-COR LI-190 quantum sensor measures photosynthetically active radiation (PAR) in the 400 to 700 nm waveband.02/09/2017HINELHALI-CORLI-190PAR
10Q99293Global PAR02/09/2017NELHAThe LI-COR LI-190 quantum sensor measures photosynthetically active radiation (PAR) in the 400 to 700 nm waveband.02/05/2019HINELHALI-CORLI-190PAR
11Q108322Global PAR02/05/2019NELHAThe LI-COR LI-190 quantum sensor measures photosynthetically active radiation (PAR) in the 400 to 700 nm waveband.04/16/2021HINELHALI-CORLI-190PAR
12Q99293Global PAR04/16/2021NELHAThe LI-COR LI-190 quantum sensor measures photosynthetically active radiation (PAR) in the 400 to 700 nm waveband.HINELHALI-CORLI-190PAR
132380Global UV04/04/2017NELHA The Apogee SU-100 total ultra-violet sensor measures UV in the 250 to 400 nm waveband.
Data is reported in both Photon Flux Density (PFD) and Energy Flux Density.
Factory generic calibration is used 5.0 Ámol/s/m2/mV and 1.65 W/m2/mV.
06/13/2019HINELHAApogeeSU-100UV
142663Global UV06/13/2019NELHA The Apogee SU-100 total ultra-violet sensor measures UV in the 250 to 400 nm waveband.
Data is reported in both Photon Flux Density (PFD) and Energy Flux Density.
Factory generic calibration is used 5.0 Ámol/s/m2/mV and 1.65 W/m2/mV.
04/16/2021HINELHAApogeeSU-100UV
151109Global UV04/16/2021NELHA The Apogee SU-200 total ultra-violet sensor measures UVA in the 300 to 400 nm waveband.
Data is reported in both Photon Flux Density (PFD) and Energy Flux Density.
Factory generic calibration is used 30 Ámol/s/m2/mV and 10 W/m2/mV.
HINELHAApogeeSU-200UV
16Logger Battery Voltage11/01/2012NELHAThe CR1000 supply voltage.HINELHACRTEMP
17Logger Temperature11/01/2012NELHATemperature of CR1000 datalogger panel. Logger is mounted inside weatherproof enclosure.HINELHABATT
18370Precipitation Gauge11/01/2012NELHAThe accumulated daily precipitation from a Met One 370 tipping bucket.HINELHARAIN
19092Station Pressure11/01/2012NELHAThe station pressure is measured by a Met One Model 092 sensor mounted inside weatherproof housing.HINELHAPRESS
2005106Wind Speed and Wind Direction11/01/2012NELHAMeasured by a marine grade R.M. Young propeller anemometer Model 05106 and integrated wind vane mounted at 10 meters on a Met One 970895 Tower.
The peak wind speed is also recorded, which is the peak 3-second running average during the 1-minute interval.
HINELHAWS