1BMSDownwelling CG403/15/201911:20:0003/15/201913:00:00The BMS Pyrgeometers (PIR and CG4) were being troubleshot during this time. A problem was discovered with the PIR cable, however there will be a few bogus or missing CG4 values during this time.
2BMSDownwelling CG403/09/201908:40:0003/09/201913:01:00Due to a scheduled NREL/SRRL power outage, to install power meters on the SRRL building, The following BMS instruments were not pointing at the sun during this time: Direct NIP, LI-201, LI-190, NIP RG780, TWC, DR02; and the following instruments were un-shaded: CG4.
3BMSDownwelling CG401/17/201707:15:0001/17/201708:56:00Due to a tripped GFCI powering the Sci-Tec tracker, The following BMS instruments were not pointing at the sun during this time: Direct CHP1 #2, NIP, DR02, LI-201, LI-190, NIP RG780, TWC; and the following instruments were un-shaded: Diffuse CM22 #1, CMP11, CG4.
4BMSDownwelling CG405/02/201509:00:0005/02/201518:53:00Due to a snagged signal cable on the Sci-Tec tracker, The following BMS instruments were not pointing at the sun during this time: Direct NIP #1, LI-201, LI-190, NIP RG780, TWC; and the following instruments were un-shaded: Diffuse CM22, CMP11, CG4.
5BMSDownwelling CG412/21/201307:00:0012/21/201316:22:00Due to a scheduled NREL power outage, to upgrade campus electrical infrastructure, The following BMS instruments were not pointing at the sun during this time: Direct NIP #1, LI-201, LI-190, NIP RG780, TWC; and the following instruments were un-shaded: Diffuse CM22, CUV4, CG4. The Middle Sci-Tec tracker for these instruments were temporarily put on a secondary UPS which failed immediately.
6BMSDownwelling CG403/02/201313:06:0003/02/201318:24:00Due to a scheduled NREL power outage, to upgrade campus power capacity, The following BMS instruments were not pointing at the sun during this time: Direct CH1, NIP #2, NIP #1, LI-201, NIP RG780, CUVA2, CUVB2, TWC; and the following instruments were un-shaded: Diffuse 8-48, PSP, CM22, CUV4, PIR, CG4. The Sci-Tec tracker for these insruments are protected by UPS, however the battery depleted at 13:06 MST (the power outage started at 8:06 MST)
7BMSDownwelling CG405/26/201206:15:0005/26/201207:12:00Due to a planned power outage for SRRL electrical work, the following BMS instruments were not following the sun: NIP #1, RG780 NIP, LI-201, TWC Photometer and the following instruments were not shaded CM22, CUV4, and CG4.
8BMSDownwelling CG409/08/201108:23:0009/08/201109:38:00Due to a planned power outage for SRRL construction activities, the following BMS instruments were not following the sun: NIP #1, RG780 NIP, LI-201, TWC Photometer and the following instruments were not shaded CM22, CUV4, and CG4.
9BMSDownwelling CG405/07/201105:55:0005/09/201107:58:00There was a planned power outage for SRRL construction activities that started at 5:18 MST. Unfortunately, the backup generator provided to SRRL was providing bad power to the UPS powering the Sci-Tec trackers, therefore the UPS failed at 5:55 MST. Unfortunately, when normal AC power was restored at 11:45 MST, the Sci-Tec trackers had lost all their configuration due to UPS cycling on and off during the outage, therefore were not tracking. The tracker settings were restored on May 9 at 7:58 MST. The following BMS instruments were not pointing at the sun during this time: Direct CH1, NIP #2, NIP #1, LI-201, NIP RG780, CUVA2, CUVB2, TWC; and the following instruments were un-shaded: Diffuse 8-48, PSP, CM22, CUV4, PIR, CG4
10BMSDownwelling CG403/18/201100:00:0003/18/201107:57:00The Sci-Tec #2 tracker was jammed on the shading plate. The following instruments were unshaded: CM22, CUV4, CG4; and the following instruments were not pointing at the sun: NIP #1, NIP RG780, LI-201, TWC Photometer.
11BMS010548Downwelling CG410/30/201000:00:0011/01/201011:27:00The Sci-Tec #2 tracker was apparently not working during this time. The following instruments were unshaded: CM22, CUV4, CG4; and the following instruments were not pointing at the sun: NIP #1, NIP RG780, LI-201.
12BMSDownwelling CG412/15/200909:40:0012/15/200910:00:00The Sci-Tec #2 tracker collided with another empty Sci-Tec tracker. The following instruments were unshaded: CM22, CUV4, CG4; and the following instruments were not pointing at the sun: NIP #1, NIP RG780, LI-201.
13BMSDownwelling CG412/09/200912:11:0012/09/200914:22:00Due to a power outage at NREL, followed by bad power, the SRRL tracker UPS shutdown. The following BMS instruments were not pointing at the sun: Direct CH1, NIP1, NIP2, NIP-RG780, LI201, TWC500, CUV4; and the following instruments were unshaded: 8-48, CM22, PSP, CUV4, PIR, CG4.
14BMS010548Downwelling CG407/30/200912:45:0007/30/200923:59:00The Sci-Tec #2 tracker was apparently not working during this time. The following instruments were unshaded: CM22, CUV4, CG4; and the following instruments were not pointing at the sun: NIP #1, NIP RG780, LI-201.
15BMSDownwelling CG411/15/200814:02:0011/15/200814:32:00Due to a planned power outage at SRRL, the following BMS instruments were unshaded: Diffuse 8-48, CM22, PSP, CUV4, DW-PIR, DW-CG4.
16BMSDownwelling CG412/29/200700:00:0001/03/200823:59:00Sci-Tec Tracker #2 had intermittent alignment problems. The following instruments were UNSHADED: Diffuse CM22, Diffuse UVB-1 and the CG4. The AOCS was not pointing at the SUN. The affected times were: 12/29/07: 13:45-sunset; 12/31/07 @ 13:30 through 1/3/08.
17BMSDownwelling CG411/28/200712:30:0011/28/200715:00:00Sci-Tec Tracker #2 had intermittent alignment problems. The following instruments were UNSHADED: Diffuse CM22, Diffuse UVB-1 and the CG4. The AOCS was not pointing at the SUN.
18BMSDownwelling CG411/05/200700:00:0011/11/200723:59:00Sci-Tec Tracker #2 had intermittent alignment problems. The following instruments were UNSHADED: Diffuse CM22, Diffuse UVB-1 and the CG4. The AOCS was not pointing at the SUN. The affected times were: 11/5: sunrise to 8:45 MST; 11/7 through 11/11.
19BMS010548Downwelling CG407/26/200607:00:0007/28/200615:30:00Instrument thermpile signal was bogus at various times throughout these three days during working hours, due to patch panel/deck cabling/data logger connection troubleshooting.
20BMS010548Downwelling CG405/25/200610:50:0005/25/200611:10:00Sci-Tec tracker #2 tracker was down due to power shutdown for installation of new SRRL equipment lift. The following instruments were UNSHADED: Diffuse CM22, Diffuse UVB-1 and the CG4.
21BMS010548Downwelling CG401/11/200614:17:0001/31/200623:59:00The CG4 was using miscalculated K-factors, during this time frame the downwelling irradiance could be off by about +/-10 W/m2. The incorrect factors were: K0=-3.37; K1=0.081; K2=1.01. The correct factors should have been: K0=-3.37; K1=0.0765; K2=1.008.
22BMS010548Downwelling CG411/05/200506:37:0011/07/200509:19:00Sci-Tec Tracker #2 was down due to a power outage on 11/4/2005 at 23:14 MST. Tracker failed to automatically reposition when power was restored on 11/5/2005 at 5:02 MST, due to failed internal battery. The following instruments were UNSHADED: Diffuse CM22, Diffuse UVB-1 and the CG4. The AOCS was not pointing at the SUN.
23BMS010548Downwelling CG407/23/200510:16:0007/25/200507:07:00Sci-Tec Tracker #2 rotated the wrong direction and hung up on the signal cables, due to a scheduled NREL power outage on 7/23/2005 at 5:33 MST. The following instruments were UNSHADED: Diffuse CM22, Diffuse UVB-1 and the CG4.
24BMS010548Downwelling CG407/10/200505:56:0007/11/200508:00:00Sci-Tec Tracker #2 rotated the wrong direction and hung up on the signal cables, due to a momenatary power loss. The following instruments were UNSHADED: Diffuse CM22, Diffuse UVB-1 and the CG4.
25BMSDownwelling CG401/07/200211:25:0003/14/200209:21:00Due to a shortage of diffuse trackers the CG4 had to be removed from service temporarily, to allow for another instrument to be calibrated under the shading ball. The Net Infrared, Downwelling Infrared, and Case Temperature for the CG4 have been forced to read zero to indicate that it's out of service.