R#SiteSerial NumberMeasurementStart DateStart TimeEnd DateEnd TimeData Quality Statement
1BMSGlobal Normal12/30/202112:33:0012/30/202116:39:00The 2-axis tracker failed under high wind conditions and is facing in a north east position, data from the following instruments should not be used until repaired:: Global Normal CMP22, SP-Lite2, LI-200R, WISER. Tracker was power cycled after the wind died down to force it resume normal tracking operations.
2BMSGlobal Normal12/15/202108:00:0012/16/202108:25:00The 2-axis tracker failed under high wind conditions and is facing in a north east position, data from the following instruments should not be used until repaired:: Global Normal CMP22, SP-Lite2, LI-200R, WISER. Tracker was power cycled the following day (with sun sensor disconnected) to force it resume normal tracking operations. Sun sensor is now connected and it seems to be working.
3BMSGlobal Normal09/17/202115:13:0009/23/202107:55:00For an experiment, the 1-axis and 2-axis trackers were placed in a 40-degree South Fixed Tilt, this affects the following instruments: Global Normal CMP22, SP-Lite2, LI-200R, WISER; Global 1-Axis CMP22, SP-Lite2, LI-200R, WISER
4BMSGlobal Normal05/12/202107:40:0005/28/202114:30:00For an experiment, Direct Normal collimating tubes were placed on the SRRL 2-Axis WISER spectroradiometer during this time. As a result the tube will be in the field of view of this global normal radiometer and may affect the data.
5BMSGlobal Normal03/17/202117:32:0003/19/202116:14:00For an experiment, the 1-axis and 2-axis trackers were placed in a 40-degree South Fixed Tilt, this affects the following instruments: Global Normal CMP22, SP-Lite2, LI-200R, WISER; Global 1-Axis CMP22, SP-Lite2, LI-200R, WISER
6BMSGlobal Normal11/17/202007:21:0011/17/202007:45:00Due to a scheduled NREL/SRRL power outage, to replace a surge protection device on the SRRL building, The following BMS instruments were not tracking the sun during this time: Global Normal CMP22, SP-Lite2, LI-200R; Global 1-Axis CMP22, SP-Lite2, LI-200R
7BMSGlobal Normal06/19/202012:14:0012/15/202119:31:00DATA CORRECTED on 12/17/2021: Irradiances were increased by 0.675% due to revised BORCAL report for all BMS shortwave radiometers calibrated in 2020 and 2021.
8BMSGlobal Normal07/28/201800:00:0007/30/201809:30:00The global normal tracker was not working during this time, data for the Global Normal CMP11 and LI-200R should not be used. Problem Unknown.
9BMSGlobal Normal07/22/201800:00:0007/23/201808:45:00The global normal tracker was not working during this time (pointed toward ground), data for the Global Normal CMP11 and LI-200R should not be used. Power cable had come unplugged to AC adapter. AC adapter was relocated to prevent future unplugging.
10BMSGlobal Normal02/21/201700:00:0002/22/201709:15:00The global normal tracker was not working during this time (pointed toward ground), data for the Global Normal CMP11 and LI-200R should not be used. Corroded connector was found at battery, replaced connector which restored 18 VDC to tracker.
11BMSGlobal Normal02/17/201700:00:0002/17/201713:00:00The global normal tracker was not working during this time (pointed toward ground), data for the Global Normal CMP11 and LI-200R should not be used.
12BMSGlobal Normal02/04/201700:00:0002/06/201709:00:00The global normal tracker was not working during this time (pointed toward ground), data for the Global Normal CMP11 and LI-200R should not be used.
13BMSGlobal Normal01/06/201700:00:0001/17/201713:50:00The global normal tracker has been having occasional tracking problems on various days during this time frame, data for the Global Normal CMP11 and LI-200R may be affected.
14BMS140840Global Normal07/04/201600:00:0007/05/201614:00:00The LICOR LI-2020 tracker is not working during this time, data should not be used during this time.
15BMS140840Global Normal01/17/201600:00:0001/18/201615:30:00The LICOR LI-2020 tracker is not working during this time, data should not be used during this time.
16BMS140840Global Normal09/21/201500:00:0009/21/201514:20:00The LICOR LI-2020 tracker is not working during this time, instrument is facing northward/downward.
17BMS140840Global Normal08/12/201512:00:0008/28/201514:00:00The LICOR LI-2020 tracker for the Global Normal CMP11 has failed. Instrument is pointed in a somewhat southeasterly direction. Tracker was replaced on 8/28/2015.
18BMS920056Global Normal09/12/201400:00:0009/15/201409:15:00The CM21 was found on 9/12/2014 with moisture inside the inner and outer dome. Instrument was removed from service on 9/15/2014 at 08:53 MST and replaced with the calibration spare (it was due to be swapped out anyway).
19BMSGlobal Normal05/08/201308:29:0005/09/201312:59:00The global normal signal cable was being replaced during this time. Data is bogus.
20BMSGlobal Normal05/06/201318:30:0005/06/201321:30:00The global normal signal cable is breaking and reporting bogus data during this time.
21BMS910056Global Normal08/16/201100:00:0008/16/201112:10:00Solar tracker was not tracking the sun and was fixed in an easterly direction. Tracker was reset at approx. 12:10 MST.
22BMS910002Global Normal03/06/201110:43:0003/09/201112:11:00Signal is negative or bogus during this time. Bendix connector at instrument was re-seated which seemed to fix the problem.
23BMSGlobal Normal09/05/201000:00:0009/07/201009:11:00The LICOR tracker for the Global Normal CM-21 was not functioning during this time. Data is bad.
24BMSGlobal Normal12/16/200214:43:0012/17/200210:57:00The J-Box on the BMS Radiometer Tower was being replaced, data from this instrument is missing or bogus.
25BMSGlobal Normal11/01/200000:00:0011/07/2000The LI-COR LI-2020 Solar Tracker is powered by a PV panel with backup battery, however the charging cycle does not work correctly. Therefore the battery does not recharge after cloud cover and the tracker stops. The battery has to be (manually) swapped with another charged battery, until the problem is corrected.