MIDC/AIM Calibration Database
Total Records: 10, displaying 1-10

R#Serial NumberCalibration FacilityCalibration DateDate for next CalibrationResponsivity [45]Calibration Factor [45]Instrument::MakeInstrument::ModelInstrument::DescriptionInstrument::ProgramInstrument::Factory CalibrationInstrument::Date of Factory CalibrationResponsivity Bins [2 deg]Responsivity Function CoefficientsOther CalibrationsCalibration FileContact PersonDocumentation TitleCalibration MethodCalibration NotesOther InformationDatalogger Entry DateResponsivity [45] [Corr]Calibration Factor [45] [Corr]Correction MethodResponsivity Bins Average [2 deg]
1Q8434SRRL2.672e18 Photons/m²/s/countLi-CorLi-190Quantum (PAR) SensorNREL/ProgramTed CannonAOCS Direct Quantum10/19/2001
2Q8434SRRL04/13/200404/13/20052.583e18 Photons/m²/s/countLi-CorLi-190Quantum (PAR) SensorNREL/ProgramAfshin Andreasvs ASD average 12:42 to 12:45 MST spectral area normalized to BMS CH1AOCS Direct QuantumCF based on area from 400-700 nm04/13/2004
3Q8434NREL10/24/200510/24/20062.461e18 Photons/m²/s/countLi-CorLi-190Quantum (PAR) SensorNREL/Program[BMS_DirPAR_2005_10.pdf]Afshin AndreasSRRL Quantum Calibration Report400-700nm vs LI-1800 Direct Photosynthetically Active Radiation (PAR)LICOR Direct Tube usedSRRL AOCS UV Radiometer10/24/2005
4Q8434NREL04/14/200804/14/20102.482e18 Photons/m²/s/countLi-CorLi-190Quantum (PAR) SensorNREL/Program[BMS_DirPAR_2008_04.pdf]Afshin AndreasSRRL Quantum Calibration Report400-700nm vs LI-1800 Direct Photosynthetically Active Radiation (PAR)LICOR Direct Tube usedSRRL AOCS UV Radiometer04/16/2008
5Q8434NREL09/28/201209/28/2014CF = 607.9 µmol/s/m²/mVLi-CorLi-190Quantum (PAR) SensorNREL/ProgramAfshin AndreasSRRL Quantum Calibration Report400-700nm vs LI-1800 Direct Photosynthetically Active Radiation (PAR)LI-1800 Direct Tube usedSRRL BMS UV Radiometer08/27/2012
6Q8434NREL11/06/201411/06/2016CF = 605.4 µmol/s/m²/mVLi-CorLi-190Quantum (PAR) SensorNREL/ProgramAfshin AndreasSRRL Quantum Calibration Report400-700nm vs LI-1800 Direct Photosynthetically Active Radiation (PAR)LI-1800 Direct Tube usedSRRL BMS UV Radiometer11/10/2014
7Q8434NREL10/31/201610/31/2018CF = 606.4 µmol/s/m²/mVLi-CorLi-190Quantum (PAR) SensorNREL/ProgramAfshin AndreasSRRL Quantum Calibration Report400-700nm vs LI-1800 Direct Photosynthetically Active Radiation (PAR)LI-1800 Direct Tube usedSRRL BMS UV Radiometer11/02/2016
8Q8434NREL05/08/201805/08/2020CF = 605.7 µmol/s/m²/mVLi-CorLi-190Quantum (PAR) SensorNREL/ProgramAfshin Andreas400-700nm vs LI-1800 Direct Photosynthetically Active Radiation (PAR)LI-1800 PRS-175 with DNI Tube used; Avg CF 10:35 - 13:30 MSTSRRL BMS UV Radiometer05/21/2018
9Q8434NREL05/22/202005/22/2022CF = 617.8 µmol/s/m²/mVLi-CorLi-190Quantum (PAR) SensorNREL/ProgramAfshin Andreas400-700nm vs S-9011 Direct Photosynthetically Active Radiation (PAR)S-9011 with DNI Tube used; Avg CF 10:30 - 11:00 MSTSRRL BMS UV Radiometer05/27/2020
10Q8434NREL08/30/202208/30/2024CF = 608.9 µmol/s/m²/mVLi-CorLi-190Quantum (PAR) SensorNREL/ProgramAfshin Andreas400-700nm vs S-9011 Direct Photosynthetically Active Radiation (PAR)S-9011 with DNI Tube used; Avg CF 9:00 - 11:30 MSTSRRL BMS UV Radiometer09/22/2022