26080033Direct Normal08/07/2019STACMounted in a Model 2AP solar tracker07/16/2020CONRELKipp & ZonenCH1DN
27010256Direct Normal07/16/2020STACMounted in a Model 2AP solar tracker06/03/2021CONRELKipp & ZonenCH1DN
28080033Direct Normal06/03/2021STACMounted in a Model 2AP solar tracker02/02/2023CONRELKipp & ZonenCH1DN
29010256Direct Normal02/02/2023STACMounted in a Model 2AP solar tracker11/14/2023CONRELKipp & ZonenCH1DN
30080033Direct Normal11/14/2023STACMounted in a Model 2AP solar trackerCONRELKipp & ZonenCH1DN
31SE-0250Direct Normal (Black Photon - Bottom)06/09/2016STACDirect (Beam) irradiance (bottom cell) as measured by a Black Photon Model BPI-IT1 mounted in a Model 2AP solar tracker.
The cell current (mA) is also reported.
CONRELBlack PhotonBPI-IT1BPB
32SE-0249Direct Normal (Black Photon - Middle)06/09/2016STACDirect (Beam) irradiance (middle cell) as measured by a Black Photon Model BPI-IT1 mounted in a Model 2AP solar tracker.
The cell current (mA) is also reported.
CONRELBlack PhotonBPI-IT1BPM
33SE-0245Direct Normal (Black Photon - Top)06/09/2016STACDirect (Beam) irradiance (top cell) as measured by a Black Photon Model BPI-IT1 mounted in a Model 2AP solar tracker.
The cell current (mA) and top cell temperature are also reported.
CONRELBlack PhotonBPI-IT1BPT
34D3530103Dry Bulb Temperature and Relative Humidity10/15/2009STACOutside air temperature and relative humidity inside in a naturally aspirated radiation shield mounted 2 meters above ground level.
The dew point temperature is calculated using both the temperature and RH.
The wind chill temperature is also calculated using the new National Weather Service (NWS) method as described on the NOAA web site.
07/12/2019CONRELVaisalaHMP50TRH
35D4220046Dry Bulb Temperature and Relative Humidity07/12/2019STACCONRELVaisalaHMP50TRH
36080017Global Horizontal10/15/2009STACIn addition to the responsvity at 45 degrees, a responsivity function (based on zenith angle) is also applied to the data.
As of 2/11/2011, the CMP22 body temperature is also recorded.
05/17/2011CONRELKipp & ZonenCMP22GH
37080018Global Horizontal05/17/2011STAC05/18/2012CONRELKipp & ZonenCMP22GH
38080015Global Horizontal05/18/2012STAC06/24/2013CONRELKipp & ZonenCMP22GH
39080018Global Horizontal06/24/2013STAC06/13/2014CONRELKipp & ZonenCMP22GH
40080015Global Horizontal06/13/2014STACAs of 13-June-2014 at 11:22 MST the responsivity function is replaced with a spline fit of the
AM/PM averaged 2-degree responsivity data (computed in the CR1000).
07/16/2015CONRELKipp & ZonenCMP22GH
41080018Global Horizontal07/16/2015STAC07/12/2019CONRELKipp & ZonenCMP22GH
42153055Global Horizontal07/12/2019STAC08/07/2019CONRELKipp & ZonenCMP11GH
43080018Global Horizontal08/07/2019STAC06/03/2021CONRELKipp & ZonenCMP22GH
44920058Global Horizontal06/03/2021STAC02/02/2023CONRELKipp & ZonenCM21GH
45080018Global Horizontal02/02/2023STAC11/14/2023CONRELKipp & ZonenCMP22GH
46920058Global Horizontal11/14/2023STACCONRELKipp & ZonenCM21GH
47Logger Battery Voltage10/15/2009STACThis battery powers both the CR1000 and communications modem. Battery is mounted inside weatherproof enclosure.
Battery is charged by 120VAC, prior to 2/11/2011 battery and solar tracker were powered by large PV system with storage battery.
CONRELBATT
48Logger Temperature10/15/2009STACTemperature of CR1000 datalogger panel. Logger is mounted inside weatherproof enclosure.CONRELCRTEMP
49Precipitation Gauge02/11/2011STACThe MetOne Model 375 tipping bucket precipitation gauge is mounted 1 meter above ground level.
The accumulated daily precipitation is also recorded.
CONRELRAIN
50D0810016Station Pressure10/15/2009STACVaisala PTB110 sensor mounted inside weatherproof enclosure.CONRELCampbell ScientificCS106PRESS