R#,"Serial Number","Measurement","Install Date","Location","Notes","Date Removed","State","Owner","Instrument_Virtual::Make","Instrument_Virtual::Model","MIDC ID" 1,N11767,Dry Bulb Temperature and Relative Humidity,11/01/2012,NELHA,Outside air temperature and relative humidity (model 083E) inside in a naturally aspirated radiation shield mounted at 2 meters.
The temperature is measured by a thermistor using the half bridge.
The dewpoint temperature is calculated by the data logger using temperature and humidity.,04/16/2021,HI,NELHA,MetOne,083E-1-13,TRH 2,N11762,Dry Bulb Temperature and Relative Humidity,04/16/2021,NELHA,Outside air temperature and relative humidity (model 083E) inside in a naturally aspirated radiation shield mounted at 2 meters.
The temperature is measured by a thermistor using the half bridge.
The dewpoint temperature is calculated by the data logger using temperature and humidity.,05/09/2022,HI,NELHA,MetOne,083E-1-13,TRH 3,N11767,Dry Bulb Temperature and Relative Humidity,05/09/2022,NELHA,Outside air temperature and relative humidity (model 083E) inside in a naturally aspirated radiation shield mounted at 2 meters.
The temperature is measured by a thermistor using the half bridge.
The dewpoint temperature is calculated by the data logger using temperature and humidity.,06/01/2022,HI,NELHA,MetOne,083E-1-13,TRH 4,N11762,Dry Bulb Temperature and Relative Humidity,06/01/2022,NELHA,Outside air temperature and relative humidity (model 083E) inside in a naturally aspirated radiation shield mounted at 2 meters.
The temperature is measured by a thermistor using the half bridge.
The dewpoint temperature is calculated by the data logger using temperature and humidity.,04/14/2023,HI,NELHA,MetOne,083E-1-13,TRH 5,N11767,Dry Bulb Temperature and Relative Humidity,04/14/2023,NELHA,Outside air temperature and relative humidity (model 083E) inside in a naturally aspirated radiation shield mounted at 2 meters.
The temperature is measured by a thermistor using the half bridge.
The dewpoint temperature is calculated by the data logger using temperature and humidity.,,HI,NELHA,MetOne,083E-1-13,TRH 6,126933,Global Horizontal,11/01/2012,NELHA,Total Hemispheric shortwave irradiance as measured by an Kipp & Zonen Thermopile Pyranometer.
Note: For data prior to 12/17/2012; negative values from the thermopile sensor were set to zero by the data logger.,04/07/2015,HI,NELHA,Kipp & Zonen,CMP11,GH 7,140710,Global Horizontal,04/07/2015,NELHA,Total Hemispheric shortwave irradiance as measured by an Kipp & Zonen Thermopile Pyranometer. ,02/09/2017,HI,NELHA,Kipp & Zonen,CMP10,GH 8,126933,Global Horizontal,02/09/2017,NELHA,Total Hemispheric shortwave irradiance as measured by an Kipp & Zonen Thermopile Pyranometer. ,02/05/2019,HI,NELHA,Kipp & Zonen,CMP11,GH 9,140710,Global Horizontal,02/05/2019,NELHA,Total Hemispheric shortwave irradiance as measured by an Kipp & Zonen Thermopile Pyranometer. ,04/16/2021,HI,NELHA,Kipp & Zonen,CMP10,GH 10,126933,Global Horizontal,04/16/2021,NELHA,Total Hemispheric shortwave irradiance as measured by an Kipp & Zonen Thermopile Pyranometer. ,04/14/2023,HI,NELHA,Kipp & Zonen,CMP11,GH 11,140710,Global Horizontal,04/14/2023,NELHA,Total Hemispheric shortwave irradiance as measured by an Kipp & Zonen Thermopile Pyranometer. ,,HI,NELHA,Kipp & Zonen,CMP10,GH 12,Q99293,Global PAR,04/23/2013,NELHA,The LI-COR LI-190 quantum sensor measures photosynthetically active radiation (PAR) in the 400 to 700 nm waveband.,04/07/2015,HI,NELHA,LI-COR,LI-190,PAR 13,Q52979,Global PAR,04/07/2015,NELHA,The LI-COR LI-190 quantum sensor measures photosynthetically active radiation (PAR) in the 400 to 700 nm waveband.,02/09/2017,HI,NELHA,LI-COR,LI-190,PAR 14,Q99293,Global PAR,02/09/2017,NELHA,The LI-COR LI-190 quantum sensor measures photosynthetically active radiation (PAR) in the 400 to 700 nm waveband.,02/05/2019,HI,NELHA,LI-COR,LI-190,PAR 15,Q108322,Global PAR,02/05/2019,NELHA,The LI-COR LI-190 quantum sensor measures photosynthetically active radiation (PAR) in the 400 to 700 nm waveband.,04/16/2021,HI,NELHA,LI-COR,LI-190,PAR 16,Q99293,Global PAR,04/16/2021,NELHA,The LI-COR LI-190 quantum sensor measures photosynthetically active radiation (PAR) in the 400 to 700 nm waveband.,04/14/2023,HI,NELHA,LI-COR,LI-190,PAR 17,Q108322,Global PAR,04/14/2023,NELHA,The LI-COR LI-190 quantum sensor measures photosynthetically active radiation (PAR) in the 400 to 700 nm waveband.,,HI,NELHA,LI-COR,LI-190,PAR 18,2380,Global UV,04/04/2017,NELHA, The Apogee SU-100 total ultra-violet sensor measures UV in the 250 to 400 nm waveband.
Data is reported in both Photon Flux Density (PFD) and Energy Flux Density.
Factory generic calibration is used 5.0 µmol/s/m2/mV and 1.65 W/m2/mV.,06/13/2019,HI,NELHA,Apogee,SU-100,UV 19,2663,Global UV,06/13/2019,NELHA, The Apogee SU-100 total ultra-violet sensor measures UV in the 250 to 400 nm waveband.
Data is reported in both Photon Flux Density (PFD) and Energy Flux Density.
Factory generic calibration is used 5.0 µmol/s/m2/mV and 1.65 W/m2/mV.,04/16/2021,HI,NELHA,Apogee,SU-100,UV 20,1109,Global UV,04/16/2021,NELHA, The Apogee SU-200 total ultra-violet sensor measures UVA in the 300 to 400 nm waveband.
Data is reported in both Photon Flux Density (PFD) and Energy Flux Density.
Factory generic calibration is used 30 µmol/s/m2/mV and 10 W/m2/mV.,08/02/2021,HI,NELHA,Apogee,SU-200,UV 21,,Logger Battery Voltage,11/01/2012,NELHA,The CR1000 supply voltage.,,HI,NELHA,,,CRTEMP 22,,Logger Temperature,11/01/2012,NELHA,Temperature of CR1000 datalogger panel. Logger is mounted inside weatherproof enclosure.,,HI,NELHA,,,BATT 23,370,Precipitation Gauge,11/01/2012,NELHA,The accumulated daily precipitation from a Met One 370 tipping bucket.,,HI,NELHA,,,RAIN 24,092,Station Pressure,11/01/2012,NELHA,The station pressure is measured by a Met One Model 092 sensor mounted inside weatherproof housing.,,HI,NELHA,,,PRESS 25,05106,Wind Speed and Wind Direction,11/01/2012,NELHA,Measured by a marine grade R.M. Young propeller anemometer Model 05106 and integrated wind vane mounted at 10 meters on a Met One 970895 Tower.
The peak wind speed is also recorded; which is the peak 3-second running average during the 1-minute interval.,,HI,NELHA,,,WS