R# | Site | Serial Number | Measurement | Start Date | Start Time | End Date | End Time | Data Quality Statement |
1 | PVSSA | | FRA2A | 12/30/2021 | 12:33:00 | 12/30/2021 | 16:39:00 | The 2-axis tracker failed under high wind conditions facing in a north east position. Tracker was power cycled later that day |
2 | PVSSA | | FRA2A | 12/15/2021 | 08:00:00 | 12/16/2021 | 08:25:00 | The 2-axis tracker failed under high wind conditions facing in a north east position. Tracker was power cycled the following day. |
3 | PVSSA | | FRA2A | 09/17/2021 | 15:13:00 | 09/23/2021 | 07:55:00 | Equinox 40S test 1-axis and 2-axis set at 40S |
4 | PVSSA | | FRA2A | 06/14/2021 | 08:30:00 | 06/30/2021 | 08:30:00 | Fraunhofer 2axis ISE cell 070-2019 removed during this time for NREL CellLab calibration - new cal not implemented |
5 | PVSSA | | FRA2A | 03/17/2021 | 17:32:00 | 03/19/2021 | 16:14:00 | Equinox 40S test 1-axis and 2-axis set at 40S |
6 | PVSSA | | FRA2A | 11/17/2020 | 07:21:00 | 11/17/2020 | 07:45:00 | Scheduled NREL/SRRL power outage trackers not operational |
7 | PVSSA | 029-2019 & 070-2019 | FRA2A | 05/01/2020 | 00:00:00 | 12/22/2020 | 11:36:00 | The 2-Axis FRA was using the wrong alpha of 0.043 %/K (SN 070-2019) and 0.044 %/K (SN 029-2019). |