MIDC/AIM Calibration Database
Total Records: 30, displaying 1-25
[Next Records]
R#Serial NumberCalibration FacilityCalibration DateDate for next CalibrationResponsivity [45]Calibration Factor [45]Instrument::MakeInstrument::ModelInstrument::DescriptionInstrument::ProgramInstrument::Factory CalibrationInstrument::Date of Factory CalibrationResponsivity Bins [2 deg]Responsivity Function CoefficientsOther CalibrationsCalibration FileContact PersonDocumentation TitleCalibration MethodCalibration NotesOther InformationDatalogger Entry DateResponsivity [45] [Corr]Calibration Factor [45] [Corr]Correction MethodResponsivity Bins Average [2 deg]
1PRS 102NREL/Optics Lab04/29/199610/29/1996Li-CorLi-1800Spectroradiometer, PortableOPTIC08/10/1994D MyersCalibration Reportreport on file, with disk
2PRS 102NREL/Optics Lab03/12/199809/12/1998Li-CorLi-1800Spectroradiometer, PortableOPTIC08/10/1994D MyersCalibration Reportwith controller DOE 02168C/Minco
3PRS 102NREL/Optics Lab05/12/199905/12/2000Li-CorLi-1800Spectroradiometer, PortableOPTIC08/10/1994[102_1999_05.zip]Afshin AndreasCalibration Reportsee report on file
4PRS 102NREL/Optics Lab01/27/200007/27/2000Li-CorLi-1800Spectroradiometer, PortableOPTIC08/10/1994[102_2000_01.zip]Afshin AndreasCalibration Reportvs F467 @ 40 Ccalib file online
5PRS 102NREL/Optics Lab07/26/200001/26/2001Li-CorLi-1800Spectroradiometer, PortableOPTIC08/10/1994[102_2000_07.zip]Afshin AndreasLI-1800 Calibration ReportDome vs F467 (7/26) Fiber vs F503 (8/21/00)both @ 40 C; (2) cal files online
6PRS 102NREL/Optics Lab01/28/200107/28/2001Li-CorLi-1800Spectroradiometer, PortableOPTIC08/10/1994[102_2001_01.zip]Afshin AndreasLI-1800 Calibration Reportvs F503 @ 40C using Dome and Fiber(2) cal files and report online
7PRS 102NREL/Optics Lab01/16/200207/16/2002Li-CorLi-1800Spectroradiometer, PortableOPTIC08/10/1994[102_2002_01.cal.zip ][102_2002_01.rpt.zip]Afshin AndreasLI-1800 PRS 102 Calibration ReportDome & Fiber vs F408 @ 40 Ccal files & report online
8PRS 102NREL/Optics Lab08/22/200202/22/2003Li-CorLi-1800Spectroradiometer, PortableOPTIC08/10/1994[102_2002_08.cal.zip ][102_2002_08.rpt.zip]Afshin AndreasLI-1800 PRS 102 Calibration ReportDome & Fiber vs F548 @ 40 Ccal files & report online
9PRS 102NREL/Optics Lab03/04/200309/04/2003Li-CorLi-1800Spectroradiometer, PortableOPTIC08/10/1994[102_2003_03.cal.zip ][102_2003_03.rpt.zip]Afshin AndreasLI-1800 PRS 102 Calibration ReportDome vs F548 @ 20 C using new temp controllercal files & report online
10PRS 102NREL/Optics Lab05/04/200411/04/2004Li-CorLi-1800Spectroradiometer, PortableOPTIC08/10/1994[102_2004_05.cal.zip ][102_2004_05.rpt.zip]Afshin AndreasLI-1800 PRS 102 Calibration ReportDome vs F408 @ 20 C using Wave-Elect. LFI-3525 @ 12.3 kOhmscal files & report onlineOUT of TOLERANCE
11PRS 102NREL/Optics Lab10/25/200404/25/2005Li-CorLi-1800Spectroradiometer, PortableOPTIC08/10/1994[102_2004_10.cal.zip ][102_2004_10.rpt.zip]Afshin AndreasLI-1800 PRS 102 Calibration ReportDome vs F571 @ 20 C using heat pipe & LFI-3525 @ 12.3 kOhmscal files & report onlineIN TOLERANCE
12PRS 102NREL/Optics Lab04/14/200510/14/2005Li-CorLi-1800Spectroradiometer, PortableOPTIC08/10/1994[102_2005_04.cal.zip ][102_2005_04.rpt.zip]Afshin AndreasLI-1800 PRS 102 Calibration ReportDome vs F571 @ 20 C using heat pipe & LFI-3525 @ 12.3 kOhmscal files & report onlineIN TOLERANCE
13PRS 102NREL/Optics Lab10/11/200504/11/2006Li-CorLi-1800Spectroradiometer, PortableOPTIC08/10/1994[102_2005_10.rpt.zip]Afshin AndreasLI-1800 PRS 102 Calibration ReportDome vs F571 @ 20 C using heat pipe & LFI-3525 @ 12.3 kOhmsReport onlineIN TOLERANCE; existing 4/14/2005 cal verified okay
14PRS 102NREL/Optics Lab04/06/200610/06/2006Li-CorLi-1800Spectroradiometer, PortableOPTIC08/10/1994[102_2006_04.cal.zip ][102_2006_04.rpt.zip]Afshin AndreasLI-1800 PRS 102 Calibration ReportDome vs F407 @ 20 C using heat pipe & LFI-3525 @ 12.3 kOhmscal files & report onlineIN TOLERANCE
15PRS 102NREL/Optics Lab10/10/200604/10/2007Li-CorLi-1800Spectroradiometer, PortableOPTIC08/10/1994[102_2006_10.rpt.zip]Afshin AndreasLI-1800 PRS 102 Calibration ReportDome vs F407 @ 20 C using heat pipe & LFI-3525 @ 12.3 kOhmsReport onlineIN TOLERANCE; existing 4/6/2006 cal verified okay
16PRS 102NREL/Optics Lab04/09/200710/09/2007Li-CorLi-1800Spectroradiometer, PortableOPTIC08/10/1994[102_2007_04.cal.zip ][102_2007_04.rpt.zip]Afshin AndreasLI-1800 PRS 102 Calibration ReportDome vs F597 @ 20 C using heat pipe & LFI-3525 @ 12.3 kOhmscal files & report onlineIN TOLERANCE
17PRS 102NREL/Optics Lab10/09/200704/09/2008Li-CorLi-1800Spectroradiometer, PortableOPTIC08/10/1994[102_2007_10.cal.zip ][102_2007_10.rpt.zip]Afshin AndreasLI-1800 PRS 102 Calibration ReportDome vs F597 @ 20 C using heat pipe & LFI-3525 @ 12.3 kOhmscal files & report onlineIN TOLERANCE
18PRS 102NREL/Optics Lab04/08/200810/08/2008Li-CorLi-1800Spectroradiometer, PortableOPTIC08/10/1994[102_2008_04.cal.zip ][102_2008_04.rpt.zip]Afshin AndreasLI-1800 PRS 102 Calibration ReportDome vs F597 @ 20 C using heat pipe & LFI-3525 @ 12.3 kOhmscal files & report onlineIN TOLERANCE
19PRS 102NREL/Optics Lab10/07/200804/07/2009Li-CorLi-1800Spectroradiometer, PortableOPTIC08/10/1994[102_2008_10.rpt.zip]Afshin AndreasLI-1800 PRS 102 Calibration ReportDome vs F597 @ 20 C using heat pipe & LFI-3525 @ 12.3 kOhmsReport onlineIN TOLERANCE; existing 4/08/2008 cal verified okay
20PRS 102NREL/Optics Lab01/19/200907/19/2009Li-CorLi-1800Spectroradiometer, PortableOPTIC08/10/1994[102_2009_01.cal.zip ][102_2009_01.rpt.zip]Afshin AndreasLI-1800 PRS 102 Calibration ReportDome vs F597 @ 40 C using LFI-3751cal files & report onlineIN TOLERANCE; temp control modification (identical to PRS 175)
21PRS 102NREL/Optics Lab09/03/200903/03/2010Li-CorLi-1800Spectroradiometer, PortableOPTIC08/10/1994[102_2009_09.cal.zip ][102_2009_09.rpt.zip]Afshin AndreasLI-1800 PRS 102 Calibration ReportDome vs F620 @ 40 C using LFI-3751cal files & report onlineIN TOLERANCE; battery replaced
22PRS 102NREL/Optics Lab02/18/201008/18/2010Li-CorLi-1800Spectroradiometer, PortableOPTIC08/10/1994[102_2010_02.cal.zip ][102_2010_02.rpt.zip]Afshin AndreasLI-1800 PRS 102 Calibration ReportDome vs F620 @ 40 C using LFI-3751cal files & report onlineIN TOLERANCE
23PRS 102NREL/Optics Lab08/12/201002/12/2011Li-CorLi-1800Spectroradiometer, PortableOPTIC08/10/1994[102_2010_08.cal.zip ][102_2010_08.rpt.zip]Afshin AndreasLI-1800 PRS 102 Calibration ReportDome vs F620 @ 40 C using LFI-3751cal files & report onlineIN TOLERANCE
24PRS 102NREL/Optics Lab02/08/201108/08/2011Li-CorLi-1800Spectroradiometer, PortableOPTIC08/10/1994[102_2011_02.cal.zip ][102_2011_02.rpt.zip]Afshin AndreasLI-1800 PRS 102 Calibration ReportDome vs F620 @ 40 C using LFI-3751cal files & report onlineIN TOLERANCE
25PRS 102NREL/Optics Lab08/09/201202/09/2013Li-CorLi-1800Spectroradiometer, PortableOPTIC08/10/1994[102_2012_08.cal.zip ][102_2012_08.rpt.zip]Afshin AndreasLI-1800 PRS 102 Calibration ReportDome vs F655 @ 40 C using LFI-3751cal files & report online; refurbished with PRS 158 mono systemOut of TOLERANCE (previous calibration state unknown)