R# | Serial Number | Calibration Facility | Calibration Date | Date for next Calibration | Responsivity [45] | Calibration Factor [45] | Instrument::Make | Instrument::Model | Instrument::Description | Instrument::Program | Instrument::Factory Calibration | Instrument::Date of Factory Calibration | Responsivity Bins [2 deg] | Responsivity Function Coefficients | Other Calibrations | Calibration File | Contact Person | Documentation Title | Calibration Method | Calibration Notes | Other Information | Datalogger Entry Date | Responsivity [45] [Corr] | Calibration Factor [45] [Corr] | Correction Method | Responsivity Bins Average [2 deg] |
1 | 010918 | NREL/Optics Lab | 04/01/2004 | 04/01/2005 | CORRECTION FACTOR =1.330 | | YES | UVA-1 | Ultraviolet Radiometer | NREL/Program | 28.60 Wm^2/V | 03/14/2005 | | | | | Daryl Myers | | 320-400nm | U95=±8.1% | OnSite (RMIS logger with 2:1 Voltage divider) | | | | | |
2 | 010918 | YES | 03/14/2005 | 03/14/2006 | 28.60 Wm^2/V | | YES | UVA-1 | Ultraviolet Radiometer | NREL/Program | 28.60 Wm^2/V | 03/14/2005 | | | | | YES | Certificate of Calibration | 320-400nm | | | | | | | |
3 | 010918 | NREL's/Optics Lab | 04/20/2006 | 04/20/2007 | Corr Fact=1.05 | | YES | UVA-1 | Ultraviolet Radiometer | NREL/Program | 28.60 Wm^2/V | 03/14/2005 | | | | | Daryl Myers | Certificate of Calibration | 320-400nm | U95=±8.0% | OnSite (RMIS logger with 2:1 Voltage divider) | | | | | |
4 | 010918 | NREL's/Optics Lab | 07/31/2008 | 07/31/2009 | CORRECTION FACTOR =1.009 | | YES | UVA-1 | Ultraviolet Radiometer | NREL/Program | 28.60 Wm^2/V | 03/14/2005 | | | | | | Certificate of Calibration | 320-400nm | | OnSite (RMIS logger with 2:1 Voltage divider) | | | | | |
5 | 010918 | Cal'd on Site | 08/13/2010 | 08/13/2011 | | Cf=0.041549 | YES | UVA-1 | Ultraviolet Radiometer | NREL/Program | 28.60 Wm^2/V | 03/14/2005 | | | | | Daryl Myers | | 320-400nm | Unc=+/-8.1% | OnSite (RMIS logger with 2:1 Voltage divider) | | | | | |
6 | 010918 | Cal'd on Site | 08/09/2011 | 08/09/2012 | CF=0.019536 W/m²/mV (w/o onsite VDIV) | CF=0.039072 W/m²/mV | YES | UVA-1 | Ultraviolet Radiometer | NREL/Program | 28.60 Wm^2/V | 03/14/2005 | | | | | Daryl Myers | | 320-400nm | Uncer ±8.3% | OnSite (RMIS logger with 2:1 Voltage divider) | | | | | |
7 | 010918 | NREL SRRL Outdoors | 04/13/2017 | 04/13/2019 | CF=0.02116 W/m²/mV (320-400nm) | CF=0.02176 W/m²/mV (315-400nm) | YES | UVA-1 | Ultraviolet Radiometer | NREL/Program | 28.60 Wm^2/V | 03/14/2005 | | | | | A.M. Andreas | | 315-400nm and 320-400nm vs PASSLite | Uncer ±4% | | | | | | |